HP StorageWorks HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide (AA-RV1VA-TE, March 2005)

Installing and Configuring the HSG Agent
140 HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide
12. Press Enter.
The computer asks you if the entered information is correct.
13. Select option y and then press the Enter key.
A message, asking if you would like to add another Client, appears.
14. To stop adding client systems, select option n and press the Enter key.
You are asked for a password, which is required to do configurations within
the Client software. If an old password is found, you are asked if you want to
use it.
Enter Subsystem Information
15. Enter your case-sensitive password that has 4 to 16 characters, and press the
Enter key. You are asked to retype the password.
16. Retype the password and press the Enter key.
Once the password has been entered, the system scans for subsystems. You
will be asked for the name and monitoring interval of each RAID subsystem
found.
17. Enter the subsystem name in lowercase letters, and press the Enter key. You
are asked for the monitoring interval. The monitoring interval is the rate at
which the Agent queries the specified subsystem for status.
18. Enter the monitoring interval in seconds, and press the Enter key. The
monitoring interval determines how often the Agent polls the subsystems. You
are asked if the displayed information is correct.
19. If the displayed information is correct, select option y and press the Enter
key.
You are asked if you want Email enabled.
Configure Email Notification Details
20. To enable the Email, select option y and press the Enter key. The software
asks for the address of the person to notify.
21. Enter the address of the person to notify, and press the Enter key.
22. From the displayed menu, enter the notification level: 1, 2, or 3.
Table 18 provides the definitions of the Email notification options: