HP StorageWorks HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide (AA-RV1VA-TE, March 2005)

FC Configuration Procedures
153HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide
When FRUTIL asks if you intend to replace the battery, answer “Y”:
Do you intend to replace this controller's cache battery? Y/N
[N] Y
FRUTIL will print out a procedure, but will not give you a prompt. Ignore the
procedure and press the Enter key.
3. Set up any additional optional controller settings, such as changing the CLI
prompt. See the
SET THIS CONTROLLER/OTHER CONTROLLER command in the HP
StorageWorks HSG60 and HSG80 Array Controller and Array Controller
Software Command Line Interface (CLI) Reference Guide for the format of
optional settings.
4. Verify that all commands have taken effect. Use the following command:
SHOW THIS
Verify node ID, allocation class, SCSI version, failover mode, identifier, and
port topology.