HP StorageWorks HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide (AA-RV1VA-TE, March 2005)

FC Configuration Procedures
159HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide
Note: Setting the SCSI version to SCSI-3 does not make the controller fully compliant
with the SCSI-3 standards.
10. Set the topology for the controller. If both ports are used, set topology for both
ports:
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
If the controller is not factory-new, it may have another topology set, in which
case these commands will result in an error message. If this happens, first take
both ports offline, then reset the topology:
SET THIS PORT_1_TOPOLOGY=OFFLINE
SET THIS PORT_2_TOPOLOGY=OFFLINE
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
Restarting the Controller
11. Restart the controller, using the following command:
RESTART THIS
It takes about a minute for the CLI prompt to come back after a RESTART
command.
Setting Time and Verifying All Commands
12. Set the time on the controller by entering the following syntax:
SET THIS TIME=DD-MMM-YYYY:HH:MM:SS
13. Use the FRUTIL utility to set up the battery discharge timer. Enter the
following command to start FRUTIL:
RUN FRUTIL
When FRUTIL asks if you intend to replace the battery, answer “Y”:
Do you intend to replace this controller's cache battery? Y/N
[N] Y
FRUTIL will print out a procedure, but will not give you a prompt. Ignore the
procedure and press Enter.