HP StorageWorks HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide (AA-RV1VA-TE, March 2005)

FC Configuration Procedures
164 HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide
Figure 39: Storage container types
Configuring a Stripeset
1. Create the stripeset by adding its name to the controller's list of storagesets
and by specifying the disk drives it contains. Use the following syntax:
ADD STRIPESET STRIPESET-NAME DISKNNNNN DISKNNNNN.......
2. Initialize the stripeset, specifying any desired switches:
INITIALIZE STRIPESET-NAME SWITCHES
See “Specifying Initialization Switches” on page 89 for a description of the
initialization switches.
3. Verify the stripeset configuration:
SHOW STRIPESET-NAME
4. Assign the stripeset a unit number to make it accessible by the hosts. See
Assigning Unit Numbers and Unit Qualifiers” on page 169.
For example:
The commands to create Stripe1, a stripeset consisting of three disks
(DISK10000, DISK20000, and DISK10100) and having a chunksize of 128:
ADD STRIPESET STRIPE1 DISK10000 DISK20000 DISK30000
INITIALIZE STRIPE1 CHUNKSIZE=128
SHOW STRIPE1
Partition
Striped mirrorset
(R0+1)
Stripeset
(R0)
RAIDset
(R3/5)
Mirrorset
(R1)
Single
devices
(JBOD)
Storagesets
Containers
CXO6677A