HP StorageWorks HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide (AA-RV1VA-TE, March 2005)

Using CLI for Configuration
182 HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide
SET THIS SCSI_VERSION=SCSI-3
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
SET OTHER PORT_1_TOPOLOGY=FABRIC
SET OTHER PORT_2_TOPOLOGY=FABRIC
SET THIS ALLOCATION_CLASS=0
RESTART OTHER
RESTART THIS
SET THIS TIME=10-Mar-2001:12:30:34
RUN FRUTIL
Y
Plug serial cable from maintenance terminal into bottom controller.
Note: Bottom controller (B) becomes “this” controller.
RUN FRUTIL
Y
SET THIS MIRRORED_CACHE
Note: This command causes the controllers to restart.
SET THIS PROMPT=“BTVS BOTTOM
SET OTHER PROMPT=“BTVS TOP”
SHOW THIS
SHOW OTHER
Plug in the Fibre Channel cable from the first adapter in host “RED.
SHOW CONNECTIONS
Do you intend to replace this controller's cache
battery? Y/N [Y]
Do you intend to replace this controller's cache
battery? Y/N [Y]