HP StorageWorks HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide (AA-RV1VA-TE, March 2005)

SWCC Agent in TruCluster Environment
239HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide
# hostname
rye.zk3.dec.com
# hwmgr -view devices
HWID: Device Name Mfg Model Location
---------------------------------------------------------------
--------
4: /dev/kevm
44: /dev/disk/floppy0c 3.5in floppy fdi0-unit-0
53: /dev/disk/cdrom0c DEC RRD47 (C) DEC bus-0-targ-5-lun-0
54: /dev/disk/dsk0c DEC HSG80 IDENTIFIER=1
55: /dev/disk/dsk1c DEC HSG80 IDENTIFIER=2
56: /dev/disk/dsk2c DEC HSG80 IDENTIFIER=3
57: /dev/disk/dsk3c DEC HSG80 IDENTIFIER=4
58: /dev/disk/dsk4c DEC HSG80 IDENTIFIER=5
59: /dev/disk/dsk5c DEC HSG80 IDENTIFIER=6
60: /dev/disk/dsk6c DEC HSG80 IDENTIFIER=7
61: /dev/ntape/tape0 DEC TLZ10 (C) DEC bus-0-targ-4-lun-0
62: /dev/cport/scp0 HSG80CCL bus-4-targ-0-lun-0
125: /dev/dmapi/dmapi
However, because SWCC looks at storage from the controller's viewpoint, units
D8, D9, and D10 appear in the Storage Window for rye even though member rye
cannot directly access these units, as shown in the Example of Confusing Storage
Display.
As another example, if you use the
/usr/opt/SWCCx/scripts/swcc_config configuration tool to make a
change to the storage subsystem information and restart the agent on one member,
you must also use the /usr/opt/SWCCx/scripts/swcc_config
configuration tool to restart the agent on all other members. If you do not do this,