HP StorageWorks HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide (AA-RV1VA-TE, March 2005)

SWCC Agent in TruCluster Environment
242 HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide
Note: When you enter the command to set multiple-bus failover and copy the
configuration information to the other controller, the other controller will restart. The
restart may set off the audible alarm (which is silenced by pressing the button on the
environmental monitoring unit (EMU)). The command line interpreter (CLI) will display
an event report, and continue reporting the condition until you clear the condition with
the clear cli command.
HSG80> set multibus copy = this
HSG80> show this
Controller:
HSG80 ZG02700662 Software V85F-0, Hardware E05
NODE_ID = 5000-1FE1-0006-3F10
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-3
Configured for MULTIBUS_FAILOVER with ZG02700619
In dual-redundant configuration
Device Port SCSI address 7
Time: 01-MAR-2001 17:48:32
Command Console LUN is lun 0 (NOIDENTIFIER)