HP StorageWorks HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide (AA-RV1VA-TE, March 2005)

SWCC Agent in TruCluster Environment
243HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide
Verify That the HSG80/HSG60 Unit Offsets Are Zero
In multiple-bus failover mode, the default offset is 0 for all host connections.
However, if a controller pair is switched from transparent failover mode to
multiple-bus failover mode, the unit offsets for transparent mode remain in effect,
so a connection can have a non-zero unit offset. For each connection to your
cluster, verify that the unit offset is 0. If the offsets are incorrect, set them and then
restart both controllers.
HSG80> show connection
Connection
Name Operating system Controller Port Address Status Offset
RYE_1 TRU64_UNIX OTHER 2 011400 OL other 0
HOST_ID=2000-0000-C922-4AAC ADAPTER_ID=1000-0000-C922-4AAC
RYE_2 TRU64_UNIX THIS 1 011400 OL this 0
HOST_ID=2000-0000-C922-4AAC ADAPTER_ID=1000-0000-C922-4AAC
RYE_3 TRU64_UNIX OTHER 1 011400 OL other 0
HOST_ID=2000-0000-C922-4AAC ADAPTER_ID=1000-0000-C922-4AAC
RYE_4 TRU64_UNIX THIS 2 011400 OL this 0
HOST_ID=2000-0000-C922-4AAC ADAPTER_ID=1000-0000-C922-4AAC
SWISS_1 TRU64_UNIX OTHER 2 011200 OL other 0
HOST_ID=2000-0000-C924-4B7B ADAPTER_ID=1000-0000-C924-4B7B
SWISS_2 TRU64_UNIX THIS 1 011200 OL this 0
HOST_ID=2000-0000-C924-4B7B ADAPTER_ID=1000-0000-C924-4B7B
SWISS_3 TRU64_UNIX OTHER 1 011200 OL other 0
HOST_ID=2000-0000-C924-4B7B ADAPTER_ID=1000-0000-C924-4B7B
SWISS_4 TRU64_UNIX THIS 2 011200 OL this 0
HOST_ID=2000-0000-C924-4B7B ADAPTER_ID=1000-0000-C924-4B7B
If an offset is not zero, you can change it as follows:
HSG80> set RYE_1 unit_offset = 0
HSG80> restart other
HSG80> restart this