HP StorageWorks HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide (AA-RV1VA-TE, March 2005)

SWCC Agent in TruCluster Environment
244 HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide
Use SCSI-3 Mode
A logical unit number (LUN) is an address of a logical unit on a virtual disk. The
Command Console LUN (CCL), also called a communications LUN, is a special
logical unit number that is used to communicate with the controller to set up the
SWCC. We recommend that you use the controller's SSCI-3 mode, which forces
the CCL to be always enabled, at LUN 0, and does not allow it to float.
Use the show this and show other commands to determine which SCSI
mode is being used.
HSG80> show this
Controller:
HSG80 ZG02700662 Software V85F-0, Hardware E05
NODE_ID = 5000-1FE1-0006-3F10
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-3
Configured for MULTIBUS_FAILOVER with ZG02700619
In dual-redundant configuration
Device Port SCSI address 7
Time: 01-MAR-2001 17:48:32
Command Console LUN is lun 0 (NOIDENTIFIER)
:
:
HSG80> show other
Controller:
HSG80 ZG02700619 Software V85F-0, Hardware E05
NODE_ID = 5000-1FE1-0006-3F10
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-3
Configured for MULTIBUS_FAILOVER with ZG02700662
In dual-redundant configuration
Device Port SCSI address 6
Time: 02-MAR-2001 18:07:48
Command Console LUN is lun 0 (NOIDENTIFIER)