HP StorageWorks HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide (AA-RV1VA-TE, March 2005)

SWCC Agent in TruCluster Environment
247HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide
Subsystem name A unique, user-defined name for each controller in a
single-controller storage configuration, and for each
controller pair in a dual-redundant configuration. Try to use a
descriptive name that will clearly identify the controller or its
location.
E-mail destination for
notification
An e-mail account that will receive error and status
information. Specifying an e-mail account is optional, and
requires that mail be already configured on the TruCluster
Server cluster. See the Cluster Administration manual for
information on configuring mail.
The agent sends a mail notification in a form similar to the
following:
From: StorageWorks_Agent@deli.zk3.dec.com
Date: Tue, 6 Mar 2001 03:29:13 -0500 (EST)
Sub: StorageWorks Agent on swiss.zk3.dec.com
This is a message from your StorageWorks
RAID Manager Software. A RAID system status
change has been detected. Corrective
action may be required! Refer to the
following status information and your Agent
Log file for more direction.
Hostname: swiss.zk3.dec.com
CRITICAL: Unable to open device -
scp0 (SP_MONITOR: MonitorSubsys)
Cluster member status If you are installing this agent in a TruCluster Server
environment, answer yes.
This option invokes the steamd -s option, which forces the
steamd daemon to rescan the SCSI busses on startup to detect
any change in device configuration.
Table 21: Required Configuration Details (Continued)
Property Description