HP StorageWorks HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide (AA-RV1VA-TE, March 2005)

Planning Storage Configurations
94 HSG80 ACS Solution Software V8.8 for Tru64 UNIX Installation and Configuration Guide
Using LOCATE Command to Find Devices
If you want to complete a storage map at a later time but do not remember where
the disk drives and partitions are located, use the CLI command
LOCATE. The LOCATE
command flashes the (fault) LED on the drives associated with the specific
storageset or unit. To turn off the flashing LEDs, enter the CLI command
LOCATE
CANCEL
.
The following procedure is an example of the commands to locate all the disk
drives that make up unit D104:
1. Enter the following command:
LOCATE D104
The LEDs on the disk drives that make up unit D104 will flash.
2. Note the position of all the drives contained within D104.
3. Enter the following command to turn off the flashing LEDs:
LOCATE CANCEL
The following procedure is an example command to locate all the drives that make
up RAIDset R1:
1. Enter the following command:
LOCATE R1
2. Note the position of all the drives contained within R1.
3. Enter the following command to turn off the flashing LEDs:
LOCATE CANCEL