HP StorageWorks HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide (AA-RV1FA-TE, March 2005)

Using CLI for Configuration
187HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide
Plug serial cable from maintenance terminal into top controller.
CLEAR CLI
SET MULTIBUS COPY=THIS
CLEAR CLI
SET THIS SCSI_VERSION=SCSI-3
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
SET OTHER PORT_1_TOPOLOGY=FABRIC
SET OTHER PORT_2_TOPOLOGY=FABRIC
SET THIS ALLOCATION_CLASS=1
RESTART OTHER
RESTART THIS
SET THIS TIME=10-Mar-2001:12:30:34
RUN FRUTIL
Y
Plug serial cable from maintenance terminal into bottom controller.
Note: Bottom controller (B) becomes “this” controller.
RUN FRUTIL
Y
SET THIS MIRRORED_CACHE
Do you intend to replace this controller's cache
battery? Y/N [Y]
Do you intend to replace this controller's cache
battery? Y/N [Y]