HP StorageWorks HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide (AA-RV1RA-TE, March 2005)

FC Configuration Procedures
131HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide
Establishing Connection with a SPARC System
To set up your SPARC system for connection with the HSG80 Controller, follow
these steps:
1. Use the supplied serial cable and the 9 to 25 pin RS-232 adapter
(P/N=12-45238-01) to connect the serial port on the SPARC system to the
serial port on the RAID array controller.
2. If you use a SUN A/B Serial Splitter Cable, and/or you attach the controller to
serial port A, you may need to modify the remote file to specify ttya as
follows:
a. Open the file /etc/remote with an editor.
b. Locate the lines:
hardwire:\
:dv:/dev/ttyb:br#9600…
c. Change ttyb to ttya.
d. Save the file.
3. Open a terminal window from the Desktop Program menu.
4. Start the Terminal Interface Program(TIP). At the prompt type:
tip hardwire
Press Enter.
5. Press Enter again, and the CLI prompt appears, similar to the following:
HSG80>