HP StorageWorks HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide (AA-RV1RA-TE, March 2005)

FC Configuration Procedures
135HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide
Note: If SCSI-2 is selected, you must disable CCL using the command:
SET THIS NOCOMMAND_CONSOLE_LUN
6. Assign an identifier for the communication LUN (also called the command
console LUN, or CCL). The CCL must have a unique identifier that is a
decimal number in the range 1 to 32767, and which is different from the
identifiers of all units. Use the following syntax:
SET THIS IDENTIFIER=N
Identifier must be unique among all the controllers attached to the fabric
within the specified allocation class.
7. Set the topology for the controller. If both ports are used, set topology for both
ports:
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
If the controller is not factory-new, it may have another topology set, in which
case these commands will result in an error message. If this happens, take
both ports offline first, then reset the topology:
SET THIS PORT_1_TOPOLOGY=OFFLINE
SET THIS PORT_2_TOPOLOGY=OFFLINE
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
Restarting the Controller
8. Restart the controller, using the following command:
RESTART THIS
Setting Time and Verifying all Commands
1. Set the time on the controller by entering the following syntax:
SET THIS TIME=DD-MMM-YYYY:HH:MM:SS
2. Use the FRUTIL utility to set up the battery discharge timer. Enter the
following command to start FRUTIL:
RUN FRUTIL
When FRUTIL asks if you intend to replace the battery, answer “Y”:
Do you intend to replace this controller's cache battery? Y/N
[N] Y