HP StorageWorks HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide (AA-RV1RA-TE, March 2005)

FC Configuration Procedures
138 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide
5. Turn on the switches, if not done previously.
If you want to communicate with the Fibre Channel switches through Telnet,
set an IP address for each switch. See the manuals that came with the switches
for details.
Plugging in the FC Cable and Verify Connections
6. Plug the Fibre Channel cable from the first host bus adapter into the switch.
Enter the SHOW CONNECTIONS command to view the connection table:
SHOW CONNECTIONS
7. Rename the connections to something meaningful to the system and easy to
remember. For example, to assign the name ANGEL1A1 to connection
!NEWCON01, enter:
RENAME !NEWCON01 ANGEL1A1
For a recommended naming convention, see Naming Connections” on
page 40.
8. Specify the operating system for the connection:
SET ANGEL1A1 OPERATING_SYSTEM=SUN
9. Verify the changes:
SHOW CONNECTIONS
Mark or tag all Fibre Channel cables at both ends for ease of maintenance.
Repeating Procedure for Each Host Adapter
10. Repeat step 7, 8, and 9 for each of that adapter’s host connections, or delete
the unused connections from the table.
11. For each host adapter, repeat steps 6 through 10.
Verifying Installation
To verify installation for your Sun Solaris host, reboot your system with the -r
option (reconfigure reboot). After the system is booted, use the f
ormat command to
verify that your LUNS are accessible.
Sun Solaris Reboot your system with the -r (reconfigure reboot).
# reboot -- -r
After the system is booted, use the
format command to verify that your LUNS are
accessible.