HP StorageWorks HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide (AA-RV1RA-TE, March 2005)

FC Configuration Procedures
142 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide
10. Set the topology for the controller. If both ports are used, set topology for both
ports:
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
If the controller is not factory-new, it may have another topology set, in which
case these commands will result in an error message. If this happens, first take
both ports offline, then reset the topology:
SET THIS PORT_1_TOPOLOGY=OFFLINE
SET THIS PORT_2_TOPOLOGY=OFFLINE
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
Restarting the Controller
11. Restart the controller, using the following command:
RESTART THIS
It takes about a minute for the CLI prompt to come back after a RESTART
command.
Setting Time and Verifying All Commands
12. Set the time on the controller by entering the following syntax:
SET THIS TIME=DD-MMM-YYYY:HH:MM:SS
13. Use the FRUTIL utility to set up the battery discharge timer. Enter the
following command to start FRUTIL:
RUN FRUTIL
When FRUTIL asks if you intend to replace the battery, answer “Y”:
Do you intend to replace this controller's cache battery? Y/N
[N] Y
FRUTIL will print out a procedure, but will not give you a prompt. Ignore the
procedure and press Enter.
14. Set up any additional optional controller settings, such as changing the CLI
prompt. See the SET THIS CONTROLLER/OTHER CONTROLLER
command in the HP StorageWorks HSG60 and HSG80 Array Controller and
Array Controller Software Command Line Interface (CLI) Reference Guide
for the format of optional settings. Perform this step on both controllers.