HP StorageWorks HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide (AA-RV1RA-TE, March 2005)

FC Configuration Procedures
150 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide
See “Specifying Initialization Switches” on page 89 for a description of the
initialization switches.
4. Verify the striped mirrorset configuration:
SHOW STRIPESET-NAME
5. Assign the stripeset mirrorset a unit number to make it accessible by the hosts.
See “Assigning Unit Numbers and Unit Qualifiers” on page 152.
For example:
The commands to create Stripe1, a striped mirrorset that comprises Mirr1, Mirr2,
and Mirr3, each of which is a two-member mirrorset:
ADD MIRRORSET MIRR1 DISK10000 DISK20000
ADD MIRRORSET MIRR2 DISK20100 DISK10100
ADD MIRRORSET MIRR3 DISK10200 DISK20200
ADD STRIPESET STRIPE1 MIRR1 MIRR2 MIRR3
INITIALIZE STRIPE1
SHOW STRIPE1
Configuring a Single-Disk Unit (JBOD)
1. Initialize the disk drive, specifying any desired switches:
INITIALIZE DISK-NAME SWITCHES
See “Specifying Initialization Switches” on page 89 for a description of the
initialization switches.
2. Verify the configuration by entering the following command:
SHOW DISK-NAME
3. Assign the disk a unit number to make it accessible by the hosts. See
Assigning Unit Numbers and Unit Qualifiers” on page 152.
Configuring a Partition
1. Initialize the storageset or disk drive, specifying any desired switches:
INITIALIZE STORAGESET-NAME SWITCHES
or
INITIALIZE DISK-NAME SWITCHES
See “Specifying Initialization Switches” on page 89 for a description of the
initialization switches.