HP StorageWorks HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide (AA-RV1RA-TE, March 2005)

FC Configuration Procedures
151HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide
2. Create each partition in the storageset or disk drive by indicating the
partition's size. Also specify any desired switch settings:
CREATE_PARTITION STORAGESET-NAME SIZE=N SWITCHES
or
CREATE_PARTITION DISK-NAME SIZE=N SWITCHES
where N is the percentage of the disk drive or storageset that will be assigned
to the partition. Enter SIZE=LARGEST, on the last partition only, to let the
controller assign the largest free space available to the partition.
Note: See the CREATE_PARTITION command in the
HP StorageWorks HSG60 and
HSG80 Array Controller and Array Controller Software Command Line Interface (CLI)
Reference Guide
for a description of the partition switches.
3. Verify the partitions:
SHOW STORAGESET-NAME
or
SHOW DISK-NAME
The partition number appears in the first column, followed by the size and
starting block of each partition.
4. Assign the partition a unit number to make it accessible by the hosts. See
Assigning Unit Numbers and Unit Qualifiers” on page 152.
For example:
The commands to create RAID1, a three-member RAIDset, then partition it into
two storage units are shown below.
ADD RAIDSET RAID1 DISK10000 DISK20000 DISK30000
INITIALIZE RAID1
CREATE_PARTITION RAID1 SIZE=25
CREATE_PARTITION RAID1 SIZE=LARGEST
SHOW RAID1