HP StorageWorks HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide (AA-RV1RA-TE, March 2005)

FC Configuration Procedures
165HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide
Analysis
Device Class: name="sd"
The device class that that is enabled. As with the loop
settings, the SCSI disk driver is used.
Adapter Path:
parent="/iommu@f,e0000000/sbus@f,e0001000/fcaw@1,0"
Identifies the adapter, the instance and the adapter/driver
name.
Target: Target=64
The default bindings for Solaris use Targets 64 and 65 for
Fabric. These values are used in conjunction with the
WWPN ( see below )
Unlike loop mode, these Targets are arbitrary; that is, they
do not correspond to an ALPA. Targets 64 and 65 are simply
used for compatibility with loop mode.
LUN: lun=0
The default logical units of 0..15 have been supplied and
may be extended to a total of 64. (See Adapter
Configuration Menu below.)
Fabric Port: wwpn="5000-1fe1-0000-13f1";
The WWPN that Solaris will attempt to bind to. This
WWPN identifies the first port on the HSG80 controller.
The /opt/steam/bin/config.sh Utility
When installing the StorageWorks RAID Manager Software, a utility script file is
loaded onto the system. While installing the kit, the user may choose an
installation directory or take the default, /opt directory These discussions assume
that the default directory was used (/opt/steam).
This utility script has many options. Refer to the Solaris documentation for more
information. Our attention here is the ability to configure either loop ALPAs or
fabric WWPNs. Both are accomplished with the
/opt/steam/bin/config.sh
script.
This version of Solution Software has relocated Option 20, “Add/Change
Adapters” to the /opt/HPfcraid/bin/config.sh file. All other options
can still be found in /opt/steam/bin.