HP StorageWorks HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide (AA-RV1RA-TE, March 2005)
FC Configuration Procedures
170 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide
As an example of Option 4, you will:
■ Change the mode from fabric to loop.
■ Change the number of LUNs per Target.
■ Change the number of LUNs per Target.
■ Set the Target IDs.
Choose Record 2, and the following dialogue takes place. (Each information
message or prompt is prefaced with a bullet).
• Driver fca-pci is configured for Fabric mode.
Change the Mode from Fabric to Loop (For JNI HBAs only)
This is always the first statement during modify and serves as a reminder of the
mode of the adapter’s driver.
• Do you want to change this mode? [y,N]
This question prompts for a change of mode. Since, in this example, the mode is
currently set to ’fabric’, answering y will set the driver for loop mode. When you
implement loop mode, the ALPAs are used for access.
NN Adapter # Control. M LN Targets Port IDs ( WWPN ) Driver Path
-- --------- -- ------- -- --- ------- ------------------ ------------
1 fcaw 0 fcaw L 16 64,65 /sbus@2,0/fcaw@2,0
2 fibre-channel 0 fca-pci F16 64 5000-1fe1-0000-0d41
/pci@a,2000/fibre-channel@2
65 5000-1fe1-0000-0d42
3 fibre-channel1 fca-pci F 16 64 5000-1fe1-0000-0d41
/pci@b,2000/fibre-channel@2
65 5000-1fe1-0000-0d42
Select record number NN (Hit RETURN to escape.):