HP StorageWorks HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide (AA-RV1RA-TE, March 2005)
Planning Storage Configurations
63HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide
Figure 20: Mapping a unit to physical disk drives
The HSG80 controller identifies devices based on a Port-Target-LUN (PTL)
numbering scheme, shown in Figure 21. The physical location of a device in its
enclosure determines its PTL.
■ P—Designates the controller's SCSI device port number (1 through 6).
■ T—Designates the target ID number of the device. Valid target ID numbers
for a single-controller configuration and dual-redundant controller
configuration are 0–3 and 8–15, respectively. (This applies to the BA370
cabinet only.)
■ L—Designates the logical unit (LUN) of the device. For disk devices the LUN
is always 0.
Figure 21: PTL naming convention
D100
RAID1
Disk 10000
Disk 20000 Disk 30000
Storageset
name
Host addressable
unit number
Controller
PTL addresses
CXO6186B
1 02 00
LUN 00
Targ et 02
Port 1