HP StorageWorks HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server 2003 (32-bit) Installation and Configuration Guide (AA-RV1XA-TE, March 2005)

Preparing the Host System
126 HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server
2003 (32-bit) Installation and Configuration Guide
b. Click the Run Fibre Channel Utility link, then choose one of the
Multi-Bus Fibre Channel setups, based on your configuration.
c. Click the SWCC link (optional) to install SWCC components.
Note: Do Not Restart the server at this time.
2. Using your Secure Path Software CD-ROM, install Secure Path 3.1A or
Secure Path 4.0 in accordance with the instructions provided with that
product. Then apply any Secure Path Service Pack download.
3. Restart the server.
4. Connect FCA to switch.
Updating Windows NT/2000 and Windows Server 2003 (32-bit) Running Secure
Path
The following procedures demonstrate how to upgrade your Solution Software in
a multiple-bus failover environment, without changing the existing Secure Path
Software.
Note: When updating a Windows NT or Windows 2000 and Windows Server 2003
(32-bit) server configuration, Secure Path must also be updated to Version 3.1A Service
Pack 2 or Version 4.0 to successfully update the FCA HBA driver.
Note: Secure Path will not be removed during this process. For updating instructions
regarding Secure Path only, see the latest Secure Path Release Notes or Web release,
found on the web site
http://www.compaq.com/products/sanworks/secure-path/index.html
Updating an Existing Standalone Server
Be sure you login to an account with administrator privileges.
1. Stop all applications that access Secure Path storage.
2. Stop Steam Agent (SWCC) in Services.