HP StorageWorks HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server 2003 (32-bit) Installation and Configuration Guide (AA-RV1XA-TE, March 2005)

Preparing the Host System
127HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server
2003 (32-bit) Installation and Configuration Guide
3. Using the Add/Remove Program in Control Panel, uninstall:
a. StorageWorks Command Console (SWCC)
b. Large LUN Utility (if installed)
Note: Do not Restart the server at this time.
4. Using your Solution Software CD-ROM, click the Solution Software v8.8
for Windows NT/2000/Server 2003 link.
a. Click the Perform FCA Driver Update link to install the HBA driver.
b. Click the Fibre Channel Software Setup link, then choose one of the
Multi-Bus Fibre Channel setups, based on your configuration.
c. Click the SWCC link (optional) to install SWCC components.
Note: For Windows NT, the latest Large LUN utility must be installed if the storage
system will be used prior to upgrading ACS to Version 8.6, and a Large LUN
configuration was previously employed.
5. Restart the server.
Updating an Existing Cluster
Be sure you login to the server with no disk resources, using an account with
administrator privileges.
1. Using Cluster Administrator, make note of your original configuration, then
move disk resources to the other cluster node. The node being updated should
not have any disk resources online. Using Cluster Manager, set all Cluster
Groups to Prevent Failback while the upgrade is taking place.
Note: Cluster Service must continue to run on all nodes. Stopping the Cluster Service
during this procedure could result in a Cluster Service failure, and subsequent
reinstallation.
2. Stop Steam Agent (SWCC) in Services.