HP StorageWorks HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server 2003 (32-bit) Installation and Configuration Guide (AA-RV1XA-TE, March 2005)

Preparing the Host System
128 HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server
2003 (32-bit) Installation and Configuration Guide
3. Using the Add/Remove Program in Control Panel, uninstall:
a. StorageWorks Command Console (SWCC).
b. Large LUN Utility (if installed)
Note: Do not Restart the system at this time.
4. Using your Solution Software CD-ROM, click the Solution Software v8.8
for Windows NT/2000/Server 2003 link.
a. Click the Perform Multi Driver Install/Update link to install the HBA
driver.
b. Click the Run Fibre Channel Software Setup link, then choose one of
the Fibre Channel setups, based on your configuration.
c. Click the SWCC link (optional) to install SWCC components.
5. Restart the updated cluster node.
6. Repeat Step 1 through Step 5 for the next cluster node.
7. Once all cluster nodes have been upgraded, using Cluster Administrator,
restore all Cluster Groups to their original Prevent Failback setting, and
restore storage groups to their original configuration.
Updating Software and Secure Path on Windows NT/2000 Server
The following procedures demonstrate how to upgrade your Solution Software, in
conjunction with your Secure Path Software, in a multiple-bus failover
environment.
Updating an Existing Standalone Server
Be sure you login to an account with administrator privileges.
1. Stop all applications that access Secure Path storage.
2. Stop Steam Agent (SWCC) in Services.
3. Using the Add/Remove Program in Control Panel, uninstall:
a. StorageWorks Command Console (SWCC)
b. Large LUN Utility (if installed)