HP StorageWorks HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server 2003 (32-bit) Installation and Configuration Guide (AA-RV1XA-TE, March 2005)

FC Configuration Procedures
181HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server
2003 (32-bit) Installation and Configuration Guide
Deleting a Storageset
Note: If the storageset you are deleting is partitioned, you must delete each partitioned
unit before you can delete the storageset.
1. Show the storageset’s configuration:
SHOW STORAGESET-NAME
2. Delete the unit number that uses the storageset. Use the following command:
DELETE UNIT-NUMBER
3. Delete the storageset. Use the following command:
DELETE STORAGESET-NAME
4. Verify the configuration:
SHOW STORAGESET-NAME
Changing Switches for a Storageset or Device
You can optimize a storageset or device at any time by changing the switches that
are associated with it. Remember to update the storageset profile when changing
its switches.
Displaying the Current Switches
To display the current switches for a storageset or single-disk unit, enter a SHOW
command, specifying the FULL switch:
SHOW STORAGESET-NAME
or
SHOW DEVICE-NAME
Note: FULL is not required when showing a particular device. It is used when showing
all devices, for example, SHOW DEVICES FULL.
Changing RAIDset and Mirrorset Switches
Use the SET storageset-name command to change the RAIDset and
Mirrorset switches associated with an existing storageset.