HP StorageWorks HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server 2003 (32-bit) Installation and Configuration Guide (AA-RV1XA-TE, March 2005)

Configuring Windows NT/Windows 2000/Windows 2003 (32-bit) Clusters
250 HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server
2003 (32-bit) Installation and Configuration Guide
enable access to all hosts on a per LUN basis using the Command Line Interface
(CLI). To enable access to the servers comprising your Windows NT/Windows
2000/Windows Server 2003 (32-bit), refer to Example 2.
Example 2 – Enabling access for specific Windows Cluster Servers
HSG80>Set D0 Enable_Access_Path = NTSERVER1, NTSERVER2
StorageWorks recommends enabling access to all connections if the only hosts on
the loop are your Windows NT/Windows 2000/Windows Server 2003 (32-bit)
Cluster servers. To enable access to all hosts on the loop, issue the CLI command
shown in Example 3. You will need to perform this command for every LUN that
will be shared among the two cluster servers.
Example 3 – Enabling access for all FC loop connections
HSG80>Set D0 Enable_Access_Path = ALL
Preparing Both Host Servers for a FC Cluster
Perform all of the steps in this section on Host A, while Host B is powered down.
When finished, power up Host B and repeat all of the steps on Host B.
Note: Follow normal procedures to POWER DOWN Host B before preparing Host A for
a cluster.
Installing the Fibre Channel Host Bus Adapter Device Driver
The Fibre Channel Host Adapter device driver is provided with your Fibre
Channel host adapter. Install the Fibre Channel host bus adapter device driver for
your server platform as described in Chapter 1 of the HSG80 ACS Solution
Software Version 8.8 for Windows NT, Windows 2000 and Windows Server 2003
(32-bit) Installation and Configuration Guide.