HP StorageWorks HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server 2003 (32-bit) Installation and Configuration Guide (AA-RV1XA-TE, March 2005)

Planning Storage Configurations
98 HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server
2003 (32-bit) Installation and Configuration Guide
The following notes describe the information contained in Table 11:
Unit D100 is a 4-member RAID 3/5 storageset named R1. R1 consists of
Disk10000, Disk20000, Disk30000, and Disk40000.
Unit D101 is a 2-member striped mirrorset named S1. S1 consists of M1 and
M2:
M1 is a 2-member mirrorset consisting of Disk10100 and Disk20100.
M2 is a 2-member mirrorset consisting of Disk30100 and Disk40100.
Unit D102 is a 2-member mirrorset named M3. M3 consists of Disk10200 and
Disk20200.
Model 4310R Disk Enclosure Shelf 2 (Single-Bus)
Bay1 2 3 4 5 6 7 8910
SCSI
ID
00 01 02 03 04 05 08 10 11 12
D100
R1
D101
S1
M1
D102
M3
D104
S2
D106
R2
D108
S3
D1
S4
M5
D2
R3
D3
S5
D4
M7
DISK
ID
Disk20000
Disk20100
Disk20200
Disk20300
Disk20400
Disk20500
Disk20800
Disk21000
Disk21100
Disk21200
Model 4310R Disk Enclosure Shelf 3 (Single-Bus)
Bay1 2 3 4 5 6 7 8910
SCSI
ID
00 01 02 03 04 05 08 10 11 12
D100
R1
D101
S1
M2
D103
M4
D104
S2
D106
R2
D108
S3
D1
S4
M6
D2
R3
D3
S5
spare
DISK
ID
Disk30000
Disk30100
Disk30200
Disk30300
Disk30400
Disk30500
Disk30800
Disk31000
Disk31100
Disk31200
Table 11: Model 4310 disk enclosure, example of storage map (Continued)