HP StorageWorks Command Console V2.5 User Guide (AA-RV1UA-TE, March 2005)

Table Of Contents
Interpreting Agent Email Messages
59Command Console V2.5 User Guide
Mapping State Change Digits to RAID System Components
Each of the 11 digits in the state change field can be mapped to a RAID system
component. Table 11 lists the digits and their relationship.
The First Digit of the State Change Field
(Overall RAID System)
The first digit in the state change field reports state changes in the overall RAID
system.
Example:
WARNING: -
Suncity HSG80 12000000000 HSG80 disks(disk21100:2)(SP_MONITOR:
MonitorSubsys)
The first digit can have one of two values:
0—Everything is fine.
1—Something has changed state.
Table 11: State Change Digit Position and Corresponding RAID System Component
State Change Digit Position
Corresponding RAID System
Component
1 Overall RAID System
2Disks
3 Power Supply
4Fans
5Battery
6 Temperature
7This Controller
8Communications LUN
9 Other Controllers
10 External Factors
11 Logical Units