HP StorageWorks HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server 2003 (32-bit) Installation and Configuration Guide (AA-RV1XA-TE, March 2005)

FC Configuration Procedures
164 HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server
2003 (32-bit) Installation and Configuration Guide
Setting Up a Controller Pair
Powering Up and Establishing Communication
1. Connect the computer or terminal to the controller as shown in Figure 38. The
connection to the computer is through the COM1 or COM2 ports.
2. Turn on the computer or terminal.
3. Apply power to the storage subsystem.
4. Configure the computer or terminal as follows:
9600 baud
8 data bits
1 stop bit
—no parity
no flow control
5. Press Enter. A copyright notice and the CLI prompt appear, indicating that
you established a local connection with the controller.
Cabling a Controller Pair
The cabling for a controller pair is shown in Figure 40.
Note: It is a good idea to plug only the controller cables into the switch. The host
cables are plugged into the switch as part of the configuration procedure (“Configuring
a Controller Pair Using CLI” on page 165).