HP StorageWorks HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server 2003 (32-bit) Installation and Configuration Guide (AA-RV1XA-TE, March 2005)

Installing, Configuring, and Removing the Client
225HSG80 ACS Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server
2003 (32-bit) Installation and Configuration Guide
Installing the Integration Patch
The integration patch determines which version of firmware the controller is using
and launches the appropriate StorageWorks Command Console (SWCC) Storage
Window within Insight Manager (CIM) version 4.23.
Should I Install the Integration Patch?
Install this patch if your HSG80 controller uses ACS 8.7 or later. This patch
enables you to use the controller’s SWCC Storage Window within CIM to monitor
and manage the controller.
Performing the Integration Patch Installation
Perform the following steps to install the integration patch.
1. Verify that you have installed the HSG80 Storage Window for ACS 8.7 or
later in the Add/Remove Programs in the Windows Control Panel. The
HSG80 Storage Window for ACS 8.7 or later is needed to display the correct
Storage Window for your version of the firmware.
2. Verify that you have installed HSG80 Storage Window version 2.1 in the
Add/Remove Programs (StorageWorks HSG80 V2.1) in the Windows Control
Panel. The HSG80 Storage Window version 2.1 is required to run the
integration patch.
3. Verify that you have installed CIM version 4.23.
4. Install the integration patch from the Solution Software CD-ROM by
double-clicking on setup.exe in the following directory:
\SWCC\Client\HSG80shim
The patch is installed in the same location as the original SWCC installation.
Caution: Do not remove the HSG80 Client from your computer. If you remove
the HSG80 Client, you will no longer be able to access its Storage Window.