HP StorageWorks HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Sun Solaris Release Notes (AA-RV1SA-TE, March 2005)

ACS Enhancements and Fixes
22 HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Sun
Solaris Release Notes
Note: Since other operating systems may not re-register their persistent reservation
settings with the array controller based upon a single unit’s persistent reservation
conflict, you must invoke the SET unit number FAKE_PR command if there are
units with devices not mounted by Tru64 UNIX (that is, units mounted by another
supported operating system).
New display information after entering the DISPLAY RESOURCES command through
VTDPY
After entering the DISPLAY RESOURCES command from the Virtual Terminal
Display (VTDPY) utility prompt, ACS now reports the number of buffers on a
specified port, the total number of buffers available, the maximum number of
buffers allowed, and the number of sense buffer structures remaining. Refer to the
HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller
Software Troubleshooting Guide for additional details regarding this change.
New display information after entering the DISPLAY HOST command through VTDPY
Incremental tallies of SFS buffer warnings are now displayed after you enter the
VTDPY DISPLAY HOST command. Refer to the HP StorageWorks HSG60 and
HSG80 Array Controller and Array Controller Software Troubleshooting Guide
for additional details regarding this change.
New Fault Management Utility commands and switches
Table 3 summarizes new Fault Management Utility (FMU) commands associated
with this update. These new commands are documented in detail in the
HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller
Software Troubleshooting Guide.
Table 3: New FMU Commands and Switches
Item FMU Command or Switch Description
1. SHOW RESERVATIONS ALL
SHOW RESERVATIONS
unit
number
Displays reservations that exist on one or more units.