HP StorageWorks HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Sun Solaris Release Notes (AA-RV1SA-TE, March 2005)

ACS Enhancements and Fixes
27HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Sun
Solaris Release Notes
16. Adding unit above
non-partitioned R5 set and
receiving Error 1170:
Partitions found on container,
unit not created.
This issue has been resolved for most cases. If there is an
error noted when this is attempted, refer to the
REINITIALIZE command in the
HP StorageWorks
HSG60 and HSG80 Array Controller and Array Controller
Software Command Line Interface Reference Guide
for
help.
17. Using the RUN CONFIG
command while bad disk
drives exist and
LFC 83030100
The RUN CONFIG command has been improved and now
skips bad disk drives after the command is submitted and
completes its routine. Previously, the controller would fail
with LFC 83030100. The system reports the following
diagnostic error information:
DEVICE AT P1:T4:L0 failed
initialization, Skipping Device
18. Controller failure and LFC
44650100
With previous ACS versions, controller restarts that resulted
in the issuance of LFC 44650100 occurred if the controller
encountered certain workloads (for example, large writes
outstanding to the controller). This issue is resolved.
19. Device error handling ACS has been improved to better handle device errors and
inconsistent drive behavior. ACS more readily ejects drives
under failure conditions to the failedset if the container is
redundant.
20. Spontaneous controller
restarts on snapshot
Controller restarts attributed to Intel i960 processor, PCI
Data or Address Line (PDAL), and Cache Data and
Address Line (CDAL) events occurred if heavy I/O load to
source units of a snapshot existed. This issue is resolved
with this release.
21. Intermittent LUN failures Under some conditions, LUNs failed to respond to SCSI
inquiries. This issue is resolved with this release.
Table 4: ACS fixes (Continued)
Item Subject Description