HP StorageWorks Replacing DIMMs in HSG60 and HSG80 Cache Modules Installation Instructions (EK-80DIM-IM. E01, March 2005)

Page 6
13. Follow on-screen instructions to install the cache module
and to restart the “other controller.”
Note: A controller restart can take as long as 60 seconds,
indicated by the temporary cycling of the port LEDs and a flashing
Reset button.
Note: If the “other controller” did not restart:
a. Press and hold the “other controller” Reset button.
b. Reseat the “other controller” program card.
c. Release the Reset button.
Tip: To verify that the “other controller” restarts, connect a PC or
terminal to the maintenance port, and then verify that it passed the
cache diagnostic test.
Caution: In step 14, entering the appropriate SET
command is critical. Enabling an incorrect Failover mode
can cause loss of data and incur system down time.
Verify the original failover configuration, and use the
appropriate SET command to restore this configuration.
14. Enable failover and reestablish the dual-redundant
configuration with the following command:
SET FAILOVER COPY=THIS_CONTROLLER
or
SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER
This command copies the subsystem configuration from
“this controller” to the “other controller.”
15. If desired, verify the failover configuration with the
following command:
SHOW THIS_CONTROLLER FULL
16. Disconnect the PC or terminal from the controller
maintenance port.