HP StorageWorks Enterprise File Services WAN Accelerator 3.0.4 installation and configuration guide (AG424-96004, March 2007)

HP STORAGEWORKS EFS WAN ACCELERATOR INSTALLATION AND CONFIGURATION GUIDE 31
2 - INSTALLING AND
C
ONFIGURING THE HP EFS
Only one type of card is allowed in the system. Up to two of the HP EFS N2c WAN
Accelerator 2-port NIC or HP EFS N2f WAN Accelerator 2-port NIC bypass cards
are allowed in the system. Up to three four-port copper Gig-E bypass cards are
allowed in the system.
Therefore, the allowable configurations are:
1- or 2- HP EFS N2c WAN Accelerator 2-port NIC
1- or 2- HP EFS N2f WAN Accelerator 2-port NIC
1-, 2-, or 3- HP EFS N4c WAN Accelerator 4-port NIC
NIC Port LabelingTerminology Note
Labeling for the NIC ports can vary. To avoid confusion, the table below outlines the
different labels for the NIC ports.
Powering On the HP EFS WAN Accelerator
The following section describes how to connect the Alternating Current (AC) power
and how to power on the HP EFS WAN Accelerator.
WARNING: Ensure that the HP EFS WAN Accelerator is properly grounded. See the HP
ProLiant DL320 Generation 4 Server User Guide or the HP ProLiant DL380 Generation 4
Server Reference and Troubleshooting Guide for more information on grounding.
To power on the HP
ProLiant DL320-520,
DL320-1020, and
DL320-2020
1. Plug the AC power cord into the HP EFS WAN Accelerator (Figure 2-4 on page
29, item 3).
2. Plug the AC power cord into an uninterrupted AC power source .
3. Press the Power On/Standby button on the front of the HP EFS WAN Accelerator
(Figure 5-1 on page 63, item 6).
4. Check the status lights on the front and rear of the HP EFS WAN Accelerator
(Figure 5-1 on page 63).
Location Label 1 Label 2
In documentation, Command Line interface, and graphical
user interface
Primary AUX
HP ProLiant DL320-520, DL320-1020, and DL320-2020 NIC1 NIC2
HP ProLiant DL380-3010 and DL380-5010 1 2