The following section describes the basic steps for configuring PBR using the
Management Console.
Basic Steps
(Client-Side)
Perform the following steps for each client-side HP EFS WAN Accelerator.
1. Configure the HP EFS WAN Accelerator as an in-path device. For detailed
information, see the HP EFS WAN Accelerator Installation and Configuration
Guide.
2. Connect to the Management Console. For detailed information, see the HP
EFS WAN Accelerator Installation and Configuration Guide.
3. Navigate to the Setup: Optimization Service - General Settings page in the
Management Console.
4. To enable PBR support, click Enable In-Path Support, Enable L4/PBR/
WCCP Support on Interface wan0_0 and Enable Optimizations on
inpath0_0, and inpath0_1.
Figure 6-2. Setup: Optimization Service - General Settings Page
5. Navigate to the Setup: Optimization Service - In-Path Rules page.