HP StorageWorks Enterprise File Services WAN Accelerator 2.1.11 release notes (392363-007, January 2007)

HP StorageWorks Enterprise File Services WAN Accelerator 2.1.11 release notes 39
3962 The CLI no longer displays an erroneous warning for the "cli default show config_hidden" command.
3960 The HP EFS WAN Accelerator checks for valid interface name in "ip in-path-gateway" setting.
3851 If an invalid job identification number is given in the "no job <job ID>" command, an error message
is now generated.
3340 The HP EFS WAN Accelerator now sends an error message if you attempt to specify a port that is
already "bound" by the HP EFS WAN Accelerator.
3001 The Management Console now displays mismatched incompatible peers (due to a software version
mismatch) in the "Connected Appliances" report.
2725 If an invalid statistics CLI command is run (for example, "stats alarm temperature rising
error-threshold 35") an internal error no longer occurs.
Documentation notes
HP StorageWorks Enterprise File Services WAN Accelerator deployment guide
The interface parameter was omitted from the "ip in-path-gateway" command. For all instances of:
ip in-path-gateway <ip address>
replace with:
ip in-path-gateway inpath0_0 <ip address>
NOTE: This interface parameter (inpath0_0) is required for version 2.x.x; it is not required for version 1.2.
In all sections describing how to configure the Cisco router, for all instances of:
ip address <ip address> 0.0.255.255
replace with:
ip address <ip address> 255.255.0.0
HP StorageWorks Enterprise File Services WAN Accelerator Command-Line
Interface reference manual
The following commands were omitted:
[no] protocol cifs opt-strict-lock enable
show protocol cifs internal
NOTE: The [no] protocol cifs opt-strict-lock enable command provides strict
optimization for the HP EFS WAN Accelerators when they do not optimize writes if the file does not have
exclusive oplock and a file is shared for read/write (for example, when PFS share mode denies both read
and write to a file).