HP StorageWorks P9000 Performance Advisor Software v5.3 User and Troubleshooting Guide (T1789-96322, August 2011)

For P9000 disk arraysFor XP disk arraysIndividual CHIP/CHA data
YesYes
The average I/Os and throughput of data
in MB/s on all the ports in the selected
CHIP/CHA
Port Details
NoYes
The individual MPs on the selected
CHIP/CHA
Yes (the port IDs are directly displayed
under the selected CHA.
Yes
The IDs of the associated ports on the
selected CHIP/CHA
YesYes
The maximum and minimum I/Os on
individual ports
YesYes
The maximum, minimum, and average
throughput of data in MB/s on individual
ports
Example:
The following image displays the CHA-1EU performance data for 53036, which belongs to the P9500
Disk Array type.
The individual performance data for CHA-1EU includes the following:
Summary:
Fibre protocol is used
Eight ports are associated with CHA-1EU
Port Activity Avg shows average I/Os as 10409.17, which is an average of the overall average
I/Os on all the eight ports. It also displays the average MB/s as 81.33, which is the an average
of the overall average MB/s on all the eight ports.
Port Details:
CL1A, CL5A, CL3A, and CL7A are the ports for CHA-1EU
Maximum and minimum I/Os
Maximum, minimum, and average throughput of data in MB/s
For example, the Max I/Os and Min I/Os for CL1A are 17290.00 and 5998.00
Related Topics
Viewing performance summary on page 206
Viewing ACP/DKA data on page 220
HP StorageWorks P9000 Performance Advisor Software User Guide 219