HP StorageWorks P9000 Performance Advisor Software v5.3 User and Troubleshooting Guide (T1789-96322, August 2011)
• The consumers displayed in the Top Components: MPB-1MB table are for MPB-1MB. These con-
sumers can be associated with multiple processing types.
• The Avg. Util % for each consumer record in the Top Components: MPB-1MB table displays the
average MPB-1MB utilization by that consumer. For example, out of the 2.50% average utilization
displayed for the Backend processing type, 0.45% is the average MPB-1MB utilization by the
consumer 0:58 (LDEV) associated with Backend.
Related Topics
• “Viewing performance summary” on page 206
• “Viewing ACP/DKA data” on page 220
• “Viewing data on Smart and ThP pools for P9000 disk arrays” on page 227
• “Utilization Summary” on page 213
• “10 busiest LDEVs/Ports” on page 231
• “10 busiest LDEVs/RAID groups” on page 232
• “Port summary” on page 235
• “Viewing LDEV data” on page 238
Viewing data on Smart and ThP pools for P9000 disk arrays
P9000 Performance Advisor provides the current configuration and performance data for the Smart
pools and the ThP pools. Smart pools contain multiple storage tiers that can be categorized as the
upper and lower tiers. The upper tiers are created from the SSD drives and used for storing frequently
accessed data. The lower tiers can be created from the SAS or the SATA drives and used for storing
less accessed data.
To view data about the different storage tiers and the RAID group utilization for a Smart or a ThP pool
on the Pool information screen, click Pools for a P9000 disk array in the Array View left pane.
Figure 15 Pool Information screen
.
IMPORTANT:
The data on the Smart pools and the ThP pools are not displayed if the pools are not configured in
the selected P9000 disk array. The following error message is displayed: Smart and ThP pools
are not configured for this P9500 Disk Array.
HP StorageWorks P9000 Performance Advisor Software User Guide 227