HP StorageWorks P9000 Performance Advisor Software v5.3 User and Troubleshooting Guide (T1789-96322, August 2011)

In the above image, under Drive Types for the P9000 disk array 53036:
Drive Types is the main category. The number (1) indicates the number of drive types available
in that category.
DKS5B-K146SS is an individual drive type.
RAID Groups is a component type. The number (12) indicates the number of RAID groups available
on the selected drive type DKS5B-K146SS.
14 is an individual RAID group.
Physical LDEVs is a component type under the RAID group 14. The number (1) indicates the
number of LDEVs associated with the selected RAID group 14. Click Physical LDEVs to see
the list of physical LDEVs that belong to the selected RAID group.
0:03 is a physical LDEV under the RAID group 14.
The RAID groups and the LDEVs that are associated with the selected drive type are also displayed
under the Back-end category. For more information, see Back-end navigation path on page 278.
The related metrics associated with the component types and the individual components in the Drive
Types category are displayed in the Choose Metrics box. Select the metrics at the component type or
the individual component levels, or both and view the related performance graphs in the Chart Work
Area. For a description of these metrics, see Metric Category, metrics, and descriptions on page 441.
HP StorageWorks P9000 Performance Advisor Software User Guide 297