HP StorageWorks P9000 Performance Advisor Software v5.3 User and Troubleshooting Guide (T1789-96322, August 2011)

7. Based on the disk array and mode of collection that you selected, following are the further course
of steps:
If you selected an XP disk array and either of the following modes of configuration data collection:
The outband mode - In this case, manually enter the SVP IP address in the SVP IP Address text
box and proceed to next step to initiate the configuration data collection.
If you already registered the XP disk array SVP with the respective management station, the
corresponding SVP IP address is displayed in the SVP IP Address text box. For more informa-
tion, see Registering the XP or P9000 disk array SVP IP address in P9000 Performance Ad-
visor on page 96.
The inband mode - In this case, proceed to next step to initiate the configuration data collection.
If you selected a P9000 disk array and either of the following modes of configuration data
collection:
The outband mode - In this case, the corresponding SVP IP address and RWC user name and
password are displayed in the respective text boxes, if you already saved these credentials
in P9000 Performance Advisor for the selected P9000 disk array. For more information on
saving credentials, see Registering the XP or P9000 disk array SVP IP address in P9000
Performance Advisor on page 96.
If you have privileges to read the disk array configuration (minimum required - Storage
Admin role with View privilege), select the Authentication Enabled check box and then
proceed to next step to initiate the configuration collection. This authentication is required
to collect configuration data of the disk array. Before enabling authentication, ensure that
you first save the credentials in the Settings > Register SVP IP/Save SVP Credentials section.
If you do not want to enable the authentication, proceed to next step to initiate the config-
uration collection. If the SVP IP address is not saved earlier, you can manually enter the
SVP IP address.
The inband mode - In this case, you can do one of the following based on your requirement:
If the command device being used for collection has authentication enabled, select the
Authentication Enabled check box. Enter the credentials (RWC user name and password)
that have privileges to use the command device, and proceed to next step to initiate the
configuration collection.
If you do not want to enable the authentication, proceed to next step to initiate the config-
uration collection.
If authentication is required and you do not enable it, the configuration data collection will fail.
8. Click Submit.
P9000 Performance Advisor collects configuration data for the XP or the P9000 disk array through
the selected command device. The Collection Status displays . The selected schedule type and
frequency appear under Frequency. After the configuration data is collected for the specified frequency,
the Collection Status displays and the Last Collection displays the updated time stamp, when P9000
Performance Advisor completes receiving the latest configuration data. The latest configuration data
is automatically updated in P9000 Performance Advisor. If there are new components that you want
to monitor, enable the associated performance data collection schedules to automatically collect data
for the new components (RAID groups and ports). For more information, see Enabling performance
collection schedules for automatic updates on page 75.
Clicking Reset restores the default settings.
Related Topics
Collecting configuration data on page 59
HP StorageWorks P9000 Performance Advisor Software User Guide 65