HP StorageWorks P9000 Performance Advisor Software v5.4 User Guide (T1789-96328, April 2012)

DescriptionScreen ele-
ments
This list displays the following options:
Time posted (default selection): If this option is selected, the time stamps of when the re-
cords are posted on the Alarm History screen are displayed. A record for a component
is first posted on the Alarm History screen when the following conditions are met:
Alarm is enabled on the component.
Performance data collection is in progress.
P9000 Performance Advisor pings the component in the next data collection cycle to re-
ceive its current performance value, and also posts a new record on the Alarm History
screen. P9000 Performance Advisor again posts a new record for the same component
and displays the new time of posting under Time Posted when one of the following con-
ditions is met:
The alarm is disabled or there are no I/Os transactions on the component.
The performance of a component rises or drops below the set threshold level.
Time updated: If this option is selected, the time stamps when P9000 Performance Advisor
last collected the latest performance values for all the components are displayed.
Time dispatched: If this option is selected, the time stamps when P9000 Performance
Advisor dispatched the alarm notifications are displayed.
If a record is showing a blank entry for any of these time stamps, that particular record is
skipped during the filtering phase. Assuming that the I/Os transactions are not happening
on a particular component, and the alarm is also disabled. In such a case, the Time Updated
displays a blank entry for that component record. Hence, the record is skipped when you
filter based on Time Updated option.
Time Stamp list
This list displays the following options:
All: This option is for viewing both the serious and the recovery alarms.
Recovery Alarm: This option is for viewing records that are logged for alarm notifications
dispatched after the performance of a component dropped below the set threshold limit.
Serious Alarm: This option is for viewing records that are logged for alarm notifications
dispatched when the performance of a component rises beyond the set threshold limit.
An alarm notification is dispatched only the first time when the performance of a compon-
ent goes beyond the set threshold limits.
Alarm Type
Select the start and end time range for filtering the component records, from the respective
calendars.
Start Time, End
Time boxes
Related Topics
Understanding alarms history on page 150
Alarm History screen on page 151
Filtering records in Alarms History table on page 153
Viewing graph of metric value's performance on page 155
Adding or removing metric values on page 138
Configuring notification and monitoring settings on page 140
Viewing performance graphs for components
P9000 Performance Advisor logs a new record in the Alarms History table when either of the following
conditions are met:
The performance of a component rises beyond the set threshold limit.
HP StorageWorks P9000 Performance Advisor Software User Guide 155