HP StorageWorks P9000 Performance Advisor Software v5.4 User Guide (T1789-96328, April 2012)

Supported disk sizes for performance estimation
The following table lists the disk arrays and the disk size they support.
Table 22 Disk types supported for performance estimation
Supported disk size in GBArray type
72 GB disk, 146 GB disk, 300 GB disk, 400 GB diskXP12000
Disks of any size.
XP24000
P9500
Understanding Performance Estimator data
Following is an example on estimating performance of an XP24000 Disk Array for the following
configuration:
Your inputs:
Disk type 15K RPM
RAID type and RAID groups 144 RAID groups for RAID 1 (2D+2D)
Workload 8K Random Writes
Intensity 4096 threads/sec
P9000 Performance Advisor estimates:
576 disks (Number of Disks) are required
I/Os on the disk set would be 46442/sec
MB/s that the array can receive per second would be 380 MB
Time taken for the array to respond (R.T (ms) for the readwrite requests would be 91 R.T (ms)
Following is an example on estimating raw and usable capacities of an XP24000 Disk Array:
Your inputs: RAID type and RAID groups 144 RAID groups for RAID 1 (2D+2D)
P9000 Performance Advisor estimates:
Raw disk capacity would be 84096 GB
Disk space available for data storage (R1/R5/R6 Usable (GB)) would be 39744 GB
The available disk space shown is only for R1/R5 RAID types.
Total or the usable storage capacity will be 39744 GB
Based on the above estimate, you can implement this configuration or modify the inputs to receive a
different configuration.
Estimating performance for XP12000 Disk Arrays
To estimate the performance for an XP12000 Disk Array:
1. Click Reports > Performance Estimator in the left pane.
The Performance Estimator screen appears.
2. Select the XP disk array model from the Array Type list. This list displays the XP disk array models
only for the monitored XP disk arrays.
Using Performance Estimator for XP and P9000 disk arrays342