HP P6000 Replication Solutions Manager Job Command Reference (T3680-96090, October 2012)

Examples
SetDrGroupFailsafe ( "\\ArrayA2\DrGrpPets", ENABLED )
Comments
Associated validation commands. None.
Agent and license prerequisites. Requires remote replication licenses on the source and
destination storage systems.
Command result value. None. For a complete list, see Command result values.
OS specifics. None.
Guidelines apply. See the HP P6000 Replication Solutions Manager User Guide for remote
replication guidelines.
See also job command SetDrGroupFailsafeOnLinkDownPowerUp.
See Resource names and UNC formats.
SetDrGroupFailsafeOnLinkDownPowerUp
Specifies whether or not virtual disks in a source DR group are automatically re-presented to hosts
after a power-up (reboot) of the source storage system when the link to the destination DR group
is down.
Syntax and arguments
When initially inserted into a job, the command syntax and default arguments are:
SetDrGroupFailsafeOnLinkdownPowerUp( %drgroup_unc_name%, DISABLED )
UNC DR Group Name (%drgroup_unc_name%). Select or enter the UNC name of the DR group to
be changed.
Failsafe On Link-down/Power-up. Select or enter the mode. Choices are enabled and disabled.
Examples
SetDrGroupFailsafeOnLinkdownPowerUp ( "\\ArrayA2\DrGrpPets", DISABLED )
Comments
Associated validation commands. None.
Agent and license prerequisites. Requires remote replication licenses on the source and
destination storage systems.
Command result value. None. For a complete list, see Command result values.
OS specifics. None.
Guidelines apply. See the HP P6000 Replication Solutions Manager User Guide for remote
replication guidelines.
See also job command SetDrGroupFailsafe.
When a job is run, some job arguments may specify features that are not available on the
target array.
See Resource names and UNC formats.
Job commands 155