HP StorageWorks XP24000 Audit Log User and Reference Guide, v01 (AE131-96003, June 2007)

user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Maintenance],Blockade,,Normal end,,,
Seq.=xxxxx
+PCB=[CHA-1P],Num. of PCBs=1+
PDEV=HDD00-01
Example 3 (blocking an LDEV)
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Maintenance],Blockade,,Normal end,,,
Seq.=xxxxx
+PG=[1-1],Num. of PGs=1
+PG=[E1-1],Num. of PGs=1 in case of an external volume
+PG=[V1-1],Num. of PGs=1 in case of a virtual volume
+LDEV=[0x00:0x03:0x2f],Num. of LDEVs=1
[Maintenance]
Maintenance function
Blockade
Blockade operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in the following table.
Table 127 Detailed Info: Blockade Operation
DescriptionItem
The cluster to be blocked.Location
Cluster-1: Block Cluster 1, Cluster-2: Block Cluster 2
The mounting location of the PCB (Channel Adapter (CHA), Disk Adapter (DKA), CM,
SM, CSW, MIX or BASE) to be blocked.
PCB
The number PCB to be blocked.Num. of PCBs
The mounting location of the PDEV (physical device) to be blocked.PDEV
The parity group number.PG
The number of parity groups.Num. of PGs
The LDEV number.LDEV
The number of LDEVs.Num. of LDEVs
XP24000 Audit Log User and Reference Guide 141