HP StorageWorks XP24000 Audit Log User and Reference Guide, v01 (AE131-96003, June 2007)

Detailed information displays for this operation, as shown in the following table.
Table 183 Detailed Info: Add Consistency Group (CTG) Operation
DescriptionItem
The LDKC number.LDKC
The consistency group number of the consistency group (CT group) newly registered.CTG
The channel type set.Path
Fibre: Fibre Channel
The value set to the offloading timer of the sidefile. The unit is minute.Offloading(min.)
Indicates whether the inflow control to the cache is enabled or disabled.Inflow Control
Enable: Setting is enabled, Disable: Setting is disabled
The setting value for Time Out (Copy Pending). The unit is minute. When Time Out (Copy
Pending) is set to 0 (zero), None is output.
Copy Pending(min.)
The setting value for Time Out (RCU ready). The unit is minute. When Time Out (RCU
ready) is set to 0 (zero), None is output.
RCU Ready(min.)
The timer type set.Timer Type
System: System timer, Local: Local timer, None: No timer (system timer)
HP XP Continuous Access Software for Mainframe - Add Pair
Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00, [TC z/OS(R)],Add Pair,,Normal end,,,
Seq.=xxxxxx
+{M-VOL(LDKC:CU:LDEV),R-VOL(LDEV),S/N,LDKC,SSID,ControllerID,Type, Initial Copy,
Fence Level,Copy Pace, Priority,Diff,CFW,DFW,CTG, Error Level,Result}=
-{0x00:0x00:0x00,0xFF,99999,0x00,0x0004,4,Async,Entire,Never,15,032,Auto,
Only M-VOL,-,0x00,Group,Normal End},
(snip)
-(snip), Num.of Pairs=xx
[TC z/OS]
HP XP Continuous Access Software for Mainframe function (for IBM z/OS)
Add Pair
Add Pair operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
XP24000 Audit Log User and Reference Guide 193