Deploying HP SIM 6.x on MSCS Clusters on Windows 2008 with SQL Server 2005 White Paper

55
Note:
These steps are to ensure HPSIM is working after failover.
10.
You can
use
the active system name to establish a command
-
line session to the cluster HP Systems
Insight Manager service from a client system that has an
OpenSSH
client installed, using SSH.
Note:
The only exception is when the disk group containing the HP SIM progr
am
files (HP SIM Disk Group in this paper) has failed
-
over to the other system.
In this case, a failing message indicating
WARNING: REMOTE HOST
IDENTIFICATION HAS CHANGED
appears. When that happens, use the
name of the other system instead.
Troubleshooting
Note:
This section is applicable only if PMP has been installed manually.
Problem
: Error during MSA tool execution.
Solution:
Execution of MSA tools might fail due to SSH key mismatch. For proper execution of MSA
tools, perform the following:
Make the pri
mary system active and execute
mxagentconfig
to push the SSH key to primary system
itself.
Make secondary system active and execute
mxagentconfig
to push the SSH key to secondary
system itself.
Problem
: Unable to Single Sign
-
On to client.
Solution:
Client
should have the certificate/name of both cluster systems in it.
If the
Trust mode
is
Trust By Certificate
on the client,
then
open the Web agent certificate,
cert.pem
file, from both the systems and import them into client Web agent.
If the
Trust mode
is
Trust By Name
on the client,
then
include both the system names in trusted server
name list.
Problem
: Unable to get the second system certificate when browsing to SMH
Solution:
Import the second system certificate on to the first system.