HP Systems Insight Manager 7.1 Release Notes
Table Of Contents
- HP Systems Insight Manager 7.1 Release Notes
- Contents
- About this document
- 1 What's new in Systems Insight Manager 7.1
- 2 Important notes
- Central Management Server
- Configure or Repair Agents
- Data Collection
- Database credentials
- Environment changes
- Discovering ESXi 4.x and 5.x and above with lockdown enabled in HP SIM 7.1
- Firmware
- Group actions
- HP Smart Update Manager
- HP Systems Insight Manager
- HP Systems Insight Manager service
- HP-UX
- Insight Remote Support
- Service Pack for ProLiant
- SNMP pass-thru
- Software/Firmware
- HP Version Control Agent
- WBEM indications
- 3 Support and other resources
- Index
3. If you discover the ESXi host in “Lockdown Enabled” mode, no credentials are required.
Neither Insight managed system setup wizard nor configure/repair agents works in “Lockdown
Enabled” mode.
4. Migration from “Lockdown Disabled” to “Lockdown Enabled” resets the credentials.
5. Migration from “Lockdown Enabled” to “Lockdown Disabled” will require a discovery task
with the appropriate credentials.
Firmware
P2000 G3 SAS array firmware(Firmware version-T230) does not support SAS Host port topology
change related events. You will not receive SAS topology WBEM events in P2000 G3 firmware.
Group actions
Group actions are supported on all versions of Integrity iLO2 and specific versions of Integrity
iLO3. For Integrity iLO3, group actions are not supported on BL860C i2, BL870C i2,BL890 C i2,
and RX2800 i2 systems. Therefore, the tasks that run group actions on these systems will fail. This
feature is enabled on BL860C i4, BL870C i4,BL890 C i4, and RX2800 i4 systems.
HP Smart Update Manager
You will encounter errors when updating iLO firmware if the existing version is less than 2.0.5.
The following conditions must be met for HP SUM to be used to update HP Version Control:
• HP Version Control must be part of a domain
• HP Version Control must have good health
• HP Version Control must be in a paired or redundant configuration
HP Systems Insight Manager
If the menus in HP SIM overlap each other, you must change internet settings.
1. Go to Tools→Internet Options.
2. Select the Security tab.
3. Select Local intranet, and then click Sites.
4. Select Automatically detect internet network.
5. Click OK.
6. Click OK.
Steps for Internet Explorer 9 are:
1. Go to Tools→Internet Options.
2. Select the Security tab.
3. Select Local intranet, and then click Sites.
4. Under Add this website to the zone:, click Add, and add the CMS site.
5. Click Close.
6. Click OK.
HP Systems Insight Manager service
When shutting down HP-UX, sometimes a message indicating HP SIM is being stopped will be
missing.
HP-UX
HP-UX version upgrade prior to 6.0 is no longer supported.
Firmware 7