Managing your HP-UX inventory with HP SIM (430146-002, January 2009)

3
2.
Edit
/var/dmi/dmiMachines
And add the DNS name of the CMS
3.
Start the DMI daemon
%/sbin/init.d/Dmisp start
HP
-
UX11iv2
SNMP, WBEM
WBEM
Install and configure WBEM services and WBEM p
roviders.
1.
Install WBEM services, WBEMSvc
s
, if not previously installed.
2.
WBEM providers “WBEMSvcs” for 11iv2 are available at HP SIM website,
http://www.hp.com/go/hpsim
. At the website, click
Download HP SIM
, then
click
HP SIM
-
HP
-
UX
,
and scroll down to the section titled,
Supporting Software for Managed Systems
to find the list of
WBEM providers. Some WBEM providers require root account access for the data to be collected,
so login as root when installing the provid
ers.
SNMP
Change the read community string and trap destination to forward the information to the
CMS.
1.
Stop the SNMP daemon:
%/sbin/init.d/SnmpMaster stop
2.
Edit
/etc/
sn
mpd.conf file
and add an appropriate
get
-
community
-
name
pertaining to the CMS
3.
Start the
SNMP daemon:
%/sbin/init.d/SnmpMaster start
Note
: For 11iv2, DMI is only supported on releases prior to September 2004. For later 11iv2
releases, WBEM is the supported solution for data collection.
HP
-
UX 11iv3
SNMP, WBEM
WBEM
Install and configure WBE
M services and WBEM providers.
1.
Install WBEM services, WBEMSvcs
, if not previously installed.
2.
WBEM providers “WBEMSvcs”
for 11iv3
are available at HP SIM website,
http://www.hp.com/go/hpsim
. At the website, click
D
ownload HP SIM
, then click
HP SIM
-
HP
-
UX
,
and scroll down to the section titled,
Supporting Software for Managed Systems
to find the list of
WBEM providers. Some WBEM providers require root account access for the data to be collected,
so login as root when
installing the providers.
SNMP
Change the read community string and trap destination to forward the information to the
CMS.
1.
Stop the SNMP daemon:
%/sbin/init.d/SnmpMaster stop
2.
Edit
/etc/
sn
mpd.conf file
and add an appropriate
get
-
community
-
name
pertaining