HP Systems Insight Manager 5.3 with Update 1 Installation and Configuration Guide for Linux HP Part Number: 418811-005 Published: April 2009 Edition: 5.3.1

c. If the the HP Server Management Drivers and Agents daemons are running, stop them using the
following command:
/etc/init.d/hpasm stop
NOTE: If the HP Server Management Drivers and Agents daemon is not installed, omit this step
and step g.
d. Stop the SNMP daemon:
/etc/init.d/snmpd stop
e. Edit the snmpd.conf file using any text editor.
For Red Hat Linux, run the following command for opening this file in the vi editor:
vi /etc/snmp/snmpd.conf
For SUSE Linux Enterprise Server 9 Service Pack 3, run the following command for opening this
file in the vi editor:
vi /etc/snmpd.conf
For SUSE Linux Enterprise Server 10 with Service Pack 1, run the following command for opening
this file in the vi editor:
vi /etc/snmp/snmpd.conf
i. Remove the comment symbol (#) from the trapsink line, and add the IP address of the CMS.
This system has HP Systems Insight Manager application running:
trapsink IPaddress
where IPaddress is the IP address of the CMS.
NOTE: If snmpd is already installed, type man snmpd and read the manpage to determine
how to configure the trapsink parameter.
NOTE: If the trapsink entry is not available in the snmpd.conf, enter it manually using the
following command:
trapsink CMS IP
where CMS IP is the location you want to send the traps from the managed nodes.
ii. If the following line exists in the read-only community:
community CommunityName IPaddress
Change it to:
rocommunity CommunityName IPaddress
If the line is not present, enter the CMS to the read-only community manually by adding the
line:
rocommunity CommunityName IPaddress
where CommunityName is the SNMP community string used by the CMS and IPaddress
is the IP address of the CMS.
iii. Save the changes to the file. To save and close this file using the vi editor, press the Esc key,
enter :wq!, and press the Enter key.
f. Start the SNMP daemon by executing the following command:
/etc/init.d/snmpd start
g. Start the HP Server Management Drivers and Agents daemon if it is installed on your system:
/etc/init.d/hpasm start
Next steps
Install and configure the required
Management Agents
on the
systems
that will be managed by the CMS.
Next, complete the initial setup of HP Systems Insight Manager. Initial setup involves adding
managed
30 Installing HP SIM on the CMS for the first time