HP Systems Insight Manager 7.0 Installation and Configuration Guide for Linux

NOTE: The initialization of the upgrade is done in the background, which takes several
minutes. To verify if the upgrade is 100% complete, view the file by executing the following
command:
more /var/opt/mx/logs/initconfig.log
NOTE: After upgrading from a previous version of HP SIM, if you notice a pre-existing
collection returning an unexpected result, and HP SIM has not been restarted since the upgrade,
then stopping and restarting the HP SIM service should resolve this problem.
5. Verify that the mxdomainmgr, mxinventory and mxdtf daemons are running by executing
the following command:
ps -ef | grep mx
If they are not running, start them by executing the following command:
/opt/mx/bin/mxstart
28 Installing HP SIM on the CMS for the first time